Fleck 5600 econominder installation software

Discussion in water softener forum, questions and answers started by borisgoodenough, jan. Install the water softener with the inlet, outlet and drain connections made according to manufacturers recommendations and to meet applicable plumbing codes. Details about fleck 5600sxt digital metered softener control valve. Level, firm surface, such as concrete, on which to place the softener tank and salt tank aka brine tank. Apr 01, 2017 find all the information related to the fleck 5600 econominder metered water softener. Apr 04, 2017 fleck 5600 general water softener installation and programming video.

Fleck 5600 sxt water softener classic design, timeless operation. Claimed advantages of the 2510 are that its motors and 1. Manually index the softener control into the in service. This system has been engineered and tested to withstand the equivalent of 27 years of uninterrupted daily use. Before beginning your installation, please first familiarize yourself with the in and out on the fleck 5600sxt meter valve. Fleck 5600 sxt on demand water softener discount water. Open a cold soft water tap nearby and let run a few minutes or until the system is free from water pressure foreign material usually solder that may have resulted a minimum of 20 pounds 1. Fleck 5600 metered water softener on demand control head.

Home water softeners autotrol fleck nelsen osmonics pentair and private label water softeners fleck pentair water softeners water softeners fleckpentair fleck 5600 metered on demand water softeners. Thank you for purchasing a new afwfilters water softener. Fleck 5600 econominder metered control valve for water. New installation guide available for fleck 5600 econominder. By the name itself you could understand one thing that it is control valve.

And the design was adopted and improved upon by hankscraft when they entered the water treatment business. Fleck 5600 general water softener installation and programming video. Model 5600 econominder installation and startup procedures. Installation instructions for water softeners with fleck 5600 and 5600sxt. Fleck parts for water softeners and filters javascript seems to be disabled in your browser. Rotate program wheel counterclockwise until it stops at regeneration position. Fleck 5600sxt digital metered softener control valve. Page 6 of 10 your 5600 econdominder water softener system is now programmed and ready for operation. Call milby company for personalized pricing 4107967700. For more information on your fleck water softener, visit our website for service.

We will provide the purpose, features and the benefits of installing one along with the fleck water softener unit. Water dispenser pentair fleck econominder 5600 troubleshooting manual 2 pages. Fleck 5600sxt digital metered softener control valve 5600 sxt head. Training in the fleck series, sxt controllers and water softener installation. If you have any doubts related to this product, feel free to post your question in the comment section. To set the program wheel, lift the people dial and rotate it so that the number of people in the. Fleck 5600 softener valve rebuild kit includes piston 6010200 seals spacers 60125 brine valve 60032. Fleck 5600 water softener is one of the most popular fleck units. Its designed with the capacity of 48,000 grains and can treat flow rates with up to 12 gpm. Apr 01, 2017 so this was all about fleck 5600 econominder metered water softener, and we believe that this helped you in the right way with getting all your concepts cleared.

Flecks most reliable and durable water softener 100% softened water 5 year warranty valve 10 years tanks. Figure 5 figure 6 next, place the fleck 5600 meter valve onto the top of the tank, being sure. Salt setting on 5600 econominder terry love plumbing. Find all the information related to the fleck 5600 econominder metered water softener. Freight charges out of maryland or virginia locations may apply. Jun 22, 2007 new installation guide available for fleck 5600 econominder we have been working on updating our installation and setup instructions for the products that we sell. Fleck 2510 econominder metered control valve for water. Fleck 5600 econominder installation guide meter dome in the back of the system like figure 5 below shows. This 5600 econominder control valve has a mechanical meter that regulates the regeneration time based on the number of gallons you have chosen. After reading the install instructions, i set the dial with water hardness 20 and people 6. Next, place the fleck 5600 meter valve onto the top of the tank, being sure.

Fleck 5600 econominder mechanical metered water softeners the fleck 5600 has been on the market for over forty years and has lasted the test of time as one was found recently still working after thirtynine years of operation. For the best experience on our site, be sure to turn on javascript in your browser. To set the time of day, push the red button and spin the 24hour gear until the present time of day is visible above the time of day arrow. New installation guide available for fleck 5600 econominder we have been working on updating our installation and setup instructions for the products that we sell. So this was all about fleck 5600 econominder metered water softener, and we believe that this helped you in the right way with getting all your concepts cleared. To program, just set the time, set the hardness and it. Programming the fleck 5600sxt softener valve for max efficiency november 8, 2016 11. Make sure to connect the inlet pipe to the fleck 5600 inlet and the outlet to the outlet see fig 2. With the the most advanced features and a simple design for easy programming the fleck 5600 sxt is a set and forget system.

Before beginning your installation, please first familiarize yourself with the in and out on the fleck 5600 meter valve. Our fleck 5600sxt on demand metered digital water softener is packed with all of the top available features with the simplest mechanical design at one low price. Metered water softener with 34 fleck 5600 econominder. Need to fix your 5600 econominder water softener meter. We appreciate the opportunity you have given us to provide you with better water. Fleck 5600 piston and interior parts rebuild kit this fleck 5600 piston and interior parts rebuild kit contains the most commonly replaced internal parts on the fleck 5600 water softener typically as these parts age and wear, it is recommended that they be replaced together as a kit. Fleck 5600 softener 48,000 grain metered soft water. Hydrotech 5600 econominder water softener meter parts. The fleck 5600 ondemand metered mechanical water softener has been proven to be one of the most dependable water softener system designs for over 40 years. Fleck 5600 sxt page 1 of 16 fleck 5600 sxt installation guide getting started abc water before you assemble your new system, be sure that the following conditions have been met for placement of your softener. The 5600 fleck valve is the most popular water softener control valve on the planet, and offers a rigid noryl valve body with low power consumption and a precision pistonsealspacer assembly.

Lubricate the bypass valve orings only on the pipe connectors with some vegetable oil or silicone grease and connect the bypass assembly to the fleck 5600 sxt control by sliding the bypass valve firmly into the body of the fleck 5600 sxt. Fleck 5600 metered water softener on demand control head valve. Manually index the softener control into the in service position and let water flow into the resin tank. Plug in the electrical cord and look in the sight hole in up procedures the back of the monitor to see that it is running. Use our part lists, interactive diagrams, accessories and expert repair advice to make your repairs easy. This is an excellent choice for larger homes due to its high flow rate.

Series 5600 ecominder water softeners owners manual. We have a generic assembly and installation page that covers nearly every type of water softener or wholehouse filter, but we also compile a list of specific questions that are. Water softener fleck 5600 series installation instructions. Please note, the fleck 5600 design came out in 1980, and remains the topselling design for residential applications.

Fleck 5600 econominder 48000 grain mechanical meter water. Fleck 5600 parts rebuild with or without replacing the timer motor fleck 5600 still getting stuck after replacing the pistons and seals kit general ionics valve or tank replacement how to set meter without the people or hardness labels on fleck econominder valves new timer motor 18743 kicks the unit into regen, but thats as far as. One of the most common questions we get here at aqua science is how to set the time of day and gallons on the fleck 5600 econominder. Fleck 5600 manual operacion y partes by puradom srl issuu. The way to tell if this part needs replacement is to remove the meter dome, turn the cable attached by hand and observe the small white gears inside. Black usa made mineral tank ships loaded for easier installation. This is a perfect option for homes with water that has medium to high hardness level. Fleck model 900091009500 service manual 40944 rev f no11 table of contents iron filter unit should be installed ahead of the water softener. Fleck 5600 from the rear showing the inlet and outlet end. If replacing an existing fleck 5600 or 2510 series valve your existing bypass or yoke can be used. I read a couple of posts and used garys calculator to locate the proper salt settingi think its approximately 18 lbs. Fleck 5600sxt digital metered softener control valve ebay. Fleck 5600 econominder installation model 5600 econominder water softener troubleshooting water purification columbus oh.

Covers standard water softeners using a separate brine tank. Use the guide below to program the correct settings. Housing wpin fleck 5600 162010 fl14448000 in stock your price. Metered l bracket fleck 5600 econominder in stock your price. We carry fleck, autotrol and softpro water softeners. Ever wonder what the different dials or gears on your water softener are for. Fleck 5600 econominder service manual pdf download. As you face the fleck 5600 control from the front, the water enters on the right and exits on the left. Install the water softener with the inlet, outlet, and drain connections made according to manufacturers recommendations and to meet applicable plumbing codes. Another problem can occur with the fleck 5600 econominder metered valve. Lubricate the bypass valve orings only on the pipe connectors with some vegetable oil or silicone grease and connect the bypass assembly to the fleck 5600sxt control by sliding the bypass valve firmly into the body of the fleck 5600sxt. The water softener should be installed with the inlet, outlet and drain connections made in accordance.

If you are installing more than one tank system the typical order for installation is. Installation video for fleck 5600sxt water softener youtube. Find fleck 5600 valves and fleck 5600 water softeners. Manually index the softener control into the service position and let water flow into the resin tank. Residential, commercial, and industrial water treatment products. Be sure to read your owners manual for any special instructions on your particular softener. Home fleck parts fleck parts 5600 5600sxt 6700 4650 since 2004 glass water systems has been a leader in economical water treatment.

Trouble shooting guide for the fleck 5600 and 5600 econominder valve. Use this water softener capacity calculator or our cylinder calculators to find the capacity of your softener complete 5600 operating manual. Fleck 5600 ondemand metered mechanical water softener. Fleck parts 5600 5600sxt 6700 4650 glass water systems. Model 5600 installation and start allow the control to draw water from the brine tank until it stops.

1338 511 561 605 836 304 1155 1283 1355 747 1020 675 666 1246 391 1026 232 663 1536 323 1472 996 73 56 1018 664 618 1309 501 761 760 360 782